Erectrochemistry System Co.,Ltd
Home Corporate guide Products Catalogue access News Contact us
japanese site site map privacy policy
 
product
LineupGeneral
Developing,Etching,StrippingTreatmentPlatingProcess controllerSpecial analyzerEquipment
Hydroxyl value, Saponification value Zinc phosphate treatment
Hydroxyl value, Saponification value analyzer Zinc phosphate treatment solution analyzer/controller
P/M alkalinity Cyanide
P/M alkalinity analyzer Cyanide analyzer
P/M alkalinity  
Automatic freezing point analyzer  
Hydroxyl value, Saponification value
Hydroxyl Value, Saponification Value Analyzer
Overview
The measurement is automatically executed only by sampling the sample and setting it in the device. It automatically measures hydroxyl value (OHV) and saponification value (SV), which are primary characteristics of polyether, alcohol, oils and fats, esters, resins, and fatty acids. It can also measure the equivalent of epoxy and acid values. It is an analysis equipment of a thorough practical valuing made up of the requirement for the analysis site of 24 hour full operation.
#1061 Hydroxyl Value, Saponification Value Analyzer
Features

(1)High-speed, a large amount of analysis
Max 18 samples can be measured, and it efficiently analyzes them in large quantities.
(2)Improvement of safety
The risk to health like the stink etc. of pyridine is canceled. It eliminates accidents in the analysis business with high safety, and a clean laboratory is achieved.
(3)Quality and reliability securing
An annoying analysis operation is simplified. Moreover, the difference by the individual variation is prevented. Speed-up and the accuracy improvement of the analytical work are achieved.
(4)Feedback of effective result
It is possible to print out the analysis result and to preserve measurement details data. It is also possible to use to various post-processinges in Excel and other analysis software like the data exploitation.
The securing traceability, the feedback to a prompter fabrication sector, and the certain data integrity is achieved.
(5)conforming to JIS analysis standard
Hydroxyl value (OHV) is measured by the phthalic anhydride process (JIS K 1557 conforming) or the acetic anhydride process.
Saponification value (SV) is measured by conforming to the JIS K 0070 standard methods for the analysis of fats and oils.

Introduction results
・Many chemical manufacturers listed on first section of the Tokyo Stock Exchange
・Chemical manufacturer in China and South Korea
etc ... a lot of plural companies
(* To defend customer's technical intelligence,our company does not open the company names to the public. )

* Our company sells this equipment through Nichiyu Techno Co., Ltd.

Nichiyu Techno Co., Ltd.
3-3 Chidori-cho, Kawasaki-ward, Kawasaki, Kanagawa, Japan
TEL: 044-280-0701 Fax: 044-280-0704
URL :http://www.nichiyu-tec.co.jp/

 

Etching
Automatic freezing point analyzer
Overview
It is a device that can automatically measure the freezing point only by setting and executing the sample. Because stirs and the temperature checks, etc. done by the hand work are done by the automatic operation, it contributes to the efficiency improvement of the analytical work so far by a compact size and an overwhelming economy.
#9552NⅡCupric Chloride Etchant Perfect Controller
Features

(1)Overwhelming cost performance
The result of our originality research and development was reflected, and a high economy was achieved compared with other companies devices.
(2)plural samples simultaneous analyses
Two samples can be measured at the same time. (It is possible to measure it also by one sample. )
(3)Comprehensible, prompt result of a measurement
If the set of the sample ends, the freezing point is automatically measured, and it displays it in the display with the graph. Moreover, data can be preserved, and the print is also possible.
(4)Highly accurate analysis
The measurement precision is within +/-0.2 degrees Celsius, corresponding to the result of the measurement by the freezing point metrology of a freezing point metrology of the JAPAN Oil Chemists' Society enactment (JOCS method) and JIS K 0065 chemical product.
(5)Wide-ranging measurement temperature
The range of the measurement temperature is -50 degrees Celsius to +130 degrees Celsius.

Composition

Main body (length 110mm and width 255mm and height 315mm )
+Note PC for control (It is possible to set it up on the main body)
+measurement unit
+printer (option)

Introduction results
・Chemical manufacturer listed on first section of the Tokyo Stock Exchange
・Pharmaceutical company listed on first section of the Tokyo Stock Exchange
・Major cosmetics manufacturer
・Asian chemical manufacturers ,etc
(* To defend customer's technical intelligence,our company does not open all the company names to the public. )

 

* Our company sells this equipment through Nichiyu Techno Co., Ltd. Nichiyu Techno Co., Ltd.

3-3 Chidori-cho, Kawasaki-ward, Kawasaki, Kanagawa, Japan
TEL: 044-280-0701 Fax: 044-280-0704
URL :http://www.nichiyu-tec.co.jp/

 

ELECTROCHEMISTRY SYSTEMS CO., LTD
5-23-1 Shinbashi, Minato-Ku,
Tokyo, 105-0004 Japan
TEL : 81-(0)3-3431-7662 FAX : 81-(0)3-5405-7250